Abb differential lock DDA 204 series:

  • Rated voltage 230...400V
  • Rated current 25A
  • 4 poles
  • Rated residual current: 300mA
  • 4 modules

Can be coupled with the magnetothermal circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to realize the magnetothermal differential protection function.

It is possible to couple the DDA 200 with the magnetic-only circuit breakers of the M 200 series, in which case additional thermal type protection must be provided for overload current protection.

Request info about this product

Abb Differential Block DDA204 25A 4 Poles 300mA 4 Modules B273212

€363.42 Tax included
€363.42

Abb Differential Block DDA204 25A 4 Poles 300mA 4 Modules B273212

€363.42
Tax included

-20€

EXTRA

Add the coupon code in the payment page

Limited-time promotion
qty

Abb Differential Block DDA204 25A 4 Poles 300mA 4 Modules B273212

€363.42

Buy it within and receive it from Monday, 29 September
Two-year warranty
Secure Payment
Easy return within 14 days

The differential blocks are mechanically designed to prevent mismating between the block and the circuit breaker: the rating of the block must always be equal to or greater than that of the circuit breaker. The plastic clamp on the side allows faster mounting of the block on the circuit breaker, and a push-button prevents possible tripping.

It is used to protect human health in the event of a ground fault (electrical leakage) or phase-to-ground electrocution, thus also providing protection against macro electrical shock, both direct and indirect, on exposed persons.

Type B differential blocks were developed for the detection of fault currents with continuous waveform or high frequency.

Characteristics:

  • Reference Standards: IEC/EN 61009 Ann. G IEC/EN 62423
  • Residual current type: Type B
  • Rated operating voltage: 230/400 V
  • Rated insulation voltage (Ui): 500 V
  • Impulse withstand voltage (Uimp): 4 kV
  • Maximum Surge Current: 3 kA
  • Leakage Current Type: B
  • Rated Frequency (f): 50/60 Hz
  • Power Loss: 3W
  • Supply Voltage Connection: Arbitrary
  • Electrical Resistance: 10000 cycle
  • Number of Poles: 4
  • Operating characteristic: Instantaneous (APR High Immunity)
  • Connection capacity: Rigid 16 ... 16 mm² - Flexible 16 ... 16 mm²
  • Ambient temperature: -25/+55 °C
  • Ambient Temperature: Operating -25/+55 °C
  • Degree of protection: IP2X
  • Dimensions: Product width: 140 mm - Product height: 93 mm - Product depth: 76 mm
  • Product net weight:0.337 kg

Data sheet

Voltage:
230/400VAC
Modules:
4
Poles:
4P
RCD Type:
B
Differential current :
0.3A
Amps:
25A
Circuit Protections: