Chint Residual current device NL1-63 25A 2P 30MA Type A 2 Modules 200209

Chint
CHT 200209 6925808309022

Chint NL1-63 Residual current device with the following characteristics:

 

  • Number of Poles: 2P
  • Rated current: 25 A
  • Type: A
  • Rated voltage: 230 Vac
  • Rated differential current: 30 mA
  • Number of Modules: 2
  • Degree of protection: IP20

     

Matching accessories: AX-5 series auxiliary contact.


Request info about this product

Chint Residual current device NL1-63 25A 2P 30MA Type A 2 Modules 200209

€41.21 Tax included
€41.21

Chint Residual current device NL1-63 25A 2P 30MA Type A 2 Modules 200209

€41.21
Tax included

-20€

EXTRA

Add the coupon code in the payment page

Limited-time promotion
qty

Chint Residual current device NL1-63 25A 2P 30MA Type A 2 Modules 200209

€41.21

Buy it within and receive it from Thursday, 13 November
klarna Pay in installments with Klarna
Two-year warranty
Easy return within 14 days

The Residual current device is used to protect people, not systems. The moment the person goes to touch it, it creates a circuit with the ground. The current instead of staying in the household circuit, uses the human body to go to ground.

 

The residual current device, also called a circuit breaker, is a device in your electrical system. It is capable of opening the circuit, that is, shutting off the power supply, the moment the current accidentally dissipates.

 

A Residual current device offers protection in case of current leakage but not in case of overvoltage. Instead, the circuit breaker is required for this type of problem.

 

The A-type earth leakage circuit breaker tripping is provided for alternating sine differential currents and pulsating unidirectional differential currents applied suddenly or slowly increasing (IEC EN 61008-1).

 

The pure earth leakage circuit breaker series NL1-63, without built-in overcurrent trip, for protection of users against direct and indirect contacts.

 

Features:

  • Reference standard: IEC/EN 61008-1
  • Number of Poles: 2P
  • Rated current: 25 A
  • Rated voltage: 230 Vac
  • Rated frequency: 50/60 Hz
  • Insulation voltage: 500 Vac
  • Impulse voltage: 6 kV
  • Conditional short-circuit current: 6 kA
  • Power Dissipation: 7 W
  • Number of DIN modules (1 DIN = 18 mm): 2
  • Degree of protection: IP20
  • Dimensions: 86x36x79 mm (HxWxD)
  • Matching accessories: AX-5 series auxiliary contact

Data sheet

Voltage:
230VAC
Modules:
2
Poles:
2P
RCD Type:
A
Differential current :
0.03A
Degree of protection:
IP20
Amps:
25A
Circuit Protections:
Residual current devices