Chint Residual current device NL1-63 40A 2P 300MA AC Type 2 Modules 200219

Chint
CHT 200219 6925808309121

Chint NL1-63 Residual current device with the following characteristics:

 

  • Number of Poles: 2P
  • Rated current: 40 A
  • Type: AC
  • Rated voltage: 230 Vac
  • Rated differential current: 300 mA
  • Number of Modules: 2
  • Degree of protection: IP20

     

Matching accessories: AX-5 series auxiliary contact.


Request info about this product

Chint Residual current device NL1-63 40A 2P 300MA AC Type 2 Modules 200219

€45.30 Tax included
€45.30

Chint Residual current device NL1-63 40A 2P 300MA AC Type 2 Modules 200219

€45.30
Tax included

-20€

EXTRA

Add the coupon code in the payment page

Limited-time promotion
qty

Chint Residual current device NL1-63 40A 2P 300MA AC Type 2 Modules 200219

€45.30

Buy it within and receive it from Tuesday, 11 November
klarna Pay in installments with Klarna
Two-year warranty
Easy return within 14 days

The Residual current device is used to protect people, not systems. The moment the person goes to touch it, it creates a circuit with the ground. The current instead of staying in the household circuit, uses the human body to go to ground.

 

The residual current device, also called a circuit breaker, is a device in your electrical system. It is capable of opening the circuit, that is, shutting off the power supply, the moment the current accidentally dissipates.

 

A Residual current device offers protection in case of current leakage but not in case of overvoltage. Instead, the circuit breaker is required for this type of problem.

 

The AC-type earth leakage circuit breaker, works only with alternating current. Almost all installations for civil use fall into this type.

 

The pure earth leakage circuit breaker series NL1-63, without built-in overcurrent releases, for the protection of users against direct and indirect contacts.


 

Features:

  • Reference standard: IEC/EN 61008-1
  • Number of Poles: 2P
  • Rated current: 40 A
  • Rated voltage: 230 Vac
  • Rated frequency: 50/60 Hz
  • Insulation voltage: 500 Vac
  • Impulse voltage: 6 kV
  • Conditional short-circuit current: 6 kA
  • Power Dissipation: 9.4 W
  • Number of DIN modules (1 DIN = 18 mm): 2
  • Degree of protection: IP20
  • Dimensions: 86x36x79 mm (HxWxD)
  • Matching accessories: AX-5 series auxiliary contact

Data sheet

Voltage:
230VAC
Modules:
2
Poles:
2P
RCD Type:
AC
Differential current :
0.03A
Degree of protection:
IP20
Amps:
40A
Circuit Protections:
Residual current devices