Chint Residual current device NL1-63 40A 2P 30MA Type F 2 Modules 263718

Chint
CHT 263718 6941339541090

Chint NL1-63 Residual current device with the following characteristics:

 

  • Number of Poles: 2P
  • Rated current: 40 A
  • Type: F
  • Rated voltage: 230 Vac
  • Rated differential current: 30 mA
  • Number of Modules: 2
  • Degree of protection: IP20


     

Matching accessories: AX-5 series auxiliary contact.


Request info about this product

Chint Residual current device NL1-63 40A 2P 30MA Type F 2 Modules 263718

€51.45 Tax included
€51.45

Chint Residual current device NL1-63 40A 2P 30MA Type F 2 Modules 263718

€51.45
Tax included

-20€

EXTRA

Add the coupon code in the payment page

Limited-time promotion
qty

Chint Residual current device NL1-63 40A 2P 30MA Type F 2 Modules 263718

€51.45

Buy it within and receive it from Tuesday, 11 November
klarna Pay in installments with Klarna
Two-year warranty
Easy return within 14 days

The Residual current deviceis used to protect people, not systems. The moment the person goes to touch it, it creates a circuit with the ground. The current instead of staying in the household circuit, uses the human body to go to ground.

 

The residual current device, also called a circuit breaker, is a device in your electrical system. It is capable of opening the circuit, that is, shutting off the power supply, the moment the current accidentally dissipates.

 

A Residual current device offers protection in case of current leakage but not in case of overvoltage. Instead, the circuit breaker is required for this type of problem.

 

F-type differential protection devices are specifically designed for single-phase inverter applications by providing an adequate level of protection in the event of a ground fault. At the same time they are able to offer high resistance to untimely tripping.

 

Pure differential circuit breakers NL1-63 series, without built-in overcurrent releases. Control of electrical circuits to protect users from direct and indirect contacts. Protection of electrical systems against the risk of fire due to insulation faults. For residential and tertiary applications. Especially suitable for the protection of new-generation household appliances equipped with power electronics and single-phase type static converters.

 

Features:

  • Reference standard: IEC/EN 61008-1; IEC/EN 62423
  • Number of Poles: 2P
  • Rated current: 25 A
  • Rated voltage: 230 Vac
  • Rated frequency: 50/60 Hz
  • Insulation voltage: 500 Vac
  • Impulse voltage: 6 kV
  • Conditional short-circuit current: 10 kA
  • Power Dissipation: 9.4 W
  • Number of DIN modules (1 DIN = 18 mm): 2
  • Degree of protection: IP20
  • Dimensions: 86x36x79 mm (HxWxD)
  • Matching accessories: AX-5 series auxiliary contact

Data sheet

Voltage:
230VAC
Modules:
2
Poles:
2P
RCD Type:
F
Differential current :
0.03A
Degree of protection:
IP20
Amps:
40A
Circuit Protections:
Residual current devices