Residual current circuit breaker kit Hager 1P+N 30MA 16A ADC816H


KIT ADC816H

Kit 5 Pieces Hager Differential Circuit Breakers with the following characteristics:

  • 2 modules
  • DIN connection (universal for any switchboard on the market)
  • Poles 1P+N
  • 16 amperes
  • Breaking capacity 4.5 kA
  • Rated operational voltage 240 Vac
  • Rated differential current 30mA
  • Type AC
  • Switching curve C.
With the kit you save compared to individually purchased items
Request info about this product

Residual current circuit breaker kit Hager 1P+N 30MA 16A ADC816H

€137.98 Tax included
€137.98

Residual current circuit breaker kit Hager 1P+N 30MA 16A ADC816H

€137.98
Tax included

-20€

EXTRA

Add the coupon code in the payment page

Limited-time promotion
qty

Residual current circuit breaker kit Hager 1P+N 30MA 16A ADC816H

€137.98

Buy it within and receive it from Thursday, 25 September
Two-year warranty
Secure Payment
Easy return within 14 days

The thermal-magnetic circuit breaker is located next to the circuit breaker and combines magnetic and thermal protection and, if necessary, interrupts the electrical current.


The thermal-magnetic circuit breaker is, therefore, a system that combines the functions of the circuit breaker with magnetic and thermal characteristics.

The thermal-magnetic differential switch in the electrical system integrates three different protections:

  • the magnetic one for short circuits that can put an entire building at risk of fire;
  • the thermal one for overloads in the supply of electrical energy (e.g. more than one household appliance in operation);
  • the differential which protects the subject from a current leakage.


The C curve, trip threshold from 5 to 10 times In, for application of ohmic-inductive circuits with medium inrush currents. It is widely used in domestic installations.


The AC residual current circuit breaker type the tripping is ensured for suddenly or slowly increasing applied sinusoidal alternating currents (CEI EN 61008-1).


Features:

  • Hager series
  • Rated operational voltage AC 240 Vac
  • Current In 16A
  • Interrupting capacity Icn 4,5kA
  • Intervention curve C
  • Rated differential current 30 mA
  • Rated insulation voltage 500 V
  • Maximum operating voltage 240 V
  • Rated fault withstand current 4000 V
  • 2 modules
  • 1P+N
  • Rated frequency 50 Hz
  • Type of protection AC differential
  • Depth 68 mm
  • Height 83 mm
  • Width 35 mm
  • Type of screw connection
  • Tightening torque 2.1 Nm
  • Protection class IP20
  • Tropicalised design for all climates
  • Operating temperature -25...40 °C

Data sheet

KIT:
Kit RCBO
Modules:
2
Poles:
1P+N
Curve:
C
Power:
4.5KA
RCD Type:
AC
Differential current :
0.03A
Amps:
16A
Circuit Protections:
RCBO