Schneider differential block with the following characteristics:

  • Number of poles: 4P
  • Number of modules: 5.5
  • Rated current: 125 amps
  • Network type: A
  • Differential sensitivity: 300 mA - 1000 mA - 500 mA
  • Differential protection timing: Instantaneous/selective adjustable
  • Mounting bracket: 35 mm symmetrical DIN rail
  • Rated operating voltage: 230/415V AC 50/60 Hz

Request info about this product

Schneider Differential Lock NG125 4P 125A 300÷1000mA I/S Type A 5.5M 19046

€486.73 Tax included
€486.73

Schneider Differential Lock NG125 4P 125A 300÷1000mA I/S Type A 5.5M 19046

€486.73
Tax included

-20€

EXTRA

Add the coupon code in the payment page

Limited-time promotion
qty

Schneider Differential Lock NG125 4P 125A 300÷1000mA I/S Type A 5.5M 19046

€486.73

Buy it within and receive it from Thursday, 13 November
klarna Pay in installments with Klarna
Two-year warranty
Easy return within 14 days

VigiNG125 is an additional modular residual current device. It has 4P and current rating of 125 A. The earth leakage protection class is type A with a sensitivity of 300 mA and voltage-independent technology. This product protects against short circuits, cable overloads, electric shocks from indirect contacts and fire hazards. This device is combined with an NG125 breaker to provide earth leakage protection and circuit protection. This product complies with IEC 60947-2.

The rated operating voltage Ue is between 230VAC and 415V AC. The rated insulation voltage Ui is 690V AC. The rated impulse withstand voltage Uimp is 8 kV. The pollution degree is 3. Can be mounted on 35 mm symmetrical DIN rail.

Width in steps of 9 mm is 11. Total dimensions are (H) 207 mm x (W) 118 mm x (D) 81 mm. The weight is 0.8 kg. The degree of protection is IP20 and IP40 in a cabinet.

The pure earth leakage circuit breaker is to protect people and not systems. The moment the person goes to touch it, it creates a circuit with the ground. The current instead of staying in the household circuit, uses the human body to go to ground.

The residual current device, also called a circuit breaker, is a device in your electrical system. It is capable of opening the circuit, that is, shutting off the power supply, the moment the current accidentally dissipates.

A pure residual current circuit breaker offers protection in case of current leakage but not in case of overvoltage. Instead, the circuit breaker is required for this type of problem.

Characteristics:

  • Rated insulation voltage: 690V AC 50/60 Hz
  • Rated impulse withstand voltage: 8 kV
  • Electrical connection to the circuit breaker: Via screws
  • 9 mm steps: 11
  • Electrical endurance: 10000 cycles
  • Terminal connections: cage terminals1050 mm² flexible - cage terminals1670 mm² rigid
  • Wire stripping length: 20 mm
  • Tightening torque: 6 Nm
  • IP degree of protection: IP40
  • Pollution degree: 3
  • Relative humidity: 95 % at 55 °C
  • Operating altitude: Acti9 iCV40 ARC

Data sheet

Type:
Earth Leakage add-on Blocks
Poles:
4P
Amps:
125A