Elettrotek Kabel marine armored cable 3x1.5 GAALSHIP HF 1000 A black 12071G73030M15

Elettrotek Kabel
EKB 12071G73030M15

Marine armored cable Elettrotek Kabel 3x1.5 GAALSHIP HF 1000A with the following characteristics:

  • No. of cores x cross section nx mm2: 3x1.5
  • Sheath color: black
  • Outer diameter approx.mm: min 22.4 Nom 23.3 Maximum 25.2
  • Maximum conductor resistance at 20°C (Ohm/km): 12.1
  • Current rating in open air at 45°C (UN): 16
  • Short circuit rating 1 second kA: 0.21
  • Cable color: black

The selling price is per meter.


This product doesn t benefit from the right of withdrawal Cable cut and therefore non-refundable
Request info about this product

Elettrotek Kabel marine armored cable 3x1.5 GAALSHIP HF 1000 A black 12071G73030M15

€3.20 Tax included
€3.20

Elettrotek Kabel marine armored cable 3x1.5 GAALSHIP HF 1000 A black 12071G73030M15

€3.20
Tax included

-20€

EXTRA

Add the coupon code in the payment page

Limited-time promotion
qty

Elettrotek Kabel marine armored cable 3x1.5 GAALSHIP HF 1000 A black 12071G73030M15

€3.20

Buy it within and receive it from Friday, 19 December
klarna Pay in installments with Klarna
Two-year warranty

Power and control cable for fixed electrical installations on board ships, not subject to mechanical hazard complying with IEC 60092-352.


Construction:

  • Conductor: plain or tinned annealed copper conductor cl. 2 flexible up to 10 mm2 cl. 5 from 16 mm2
  • Insulation: GAALTHERM® 595
  • Armor: Plain or tinned annealed copper wire braid acc. to IEC 60092-350

Approvals/Certificates:

  • RINA / RINAMIL (Italian Naval Registry)
  • BV (Veritas Office)
  • LR (Lloyd's Register)
  • DNV-GL (Det Norske Veritas - Germanisher Lloyd) ongoing
  • ABS (American Bureau of Shipping)
  • RMRS (Russian Maritime Registry of Shipping)

Technical data:

  • Rated voltage: Uo/U 0.6/1 kV
  • Test voltage: 3.5 kV
  • Temperature range: -40°C to +90°C
  • Installation temperature: -5°C

Features:

  • Sheath and insulation materials according to: IEC 60092-360
  • Design guidelines acc. to IEC 60092-350/353
  • Selection and installation of electrical cables acc. to IEC 60092-352
  • Cold bending test at low temperatures
  • Impact of cold bending at low temperatures

Data sheet

Colour:
Black
Section:
1.5mmq
Number of cables:
3