Eaton Motor Protection Circuit Breaker 3P 1-1.6A 72735


EAO 72735 4015080727354

Motor protection switch for Eaton motor protection, with the following characteristics

  • 3 poles - size PKZM0
  • With adjustable thermal trip and instantaneous magnetic trip
  • Rated operational voltage Ue 690V
  • Rated operational current 1.6 A
  • Power 0.55 kW
  • Overload releases 1 - 1.6 A
  • Rated frequency 40 - 60 Hz
Request info about this product

Eaton Motor Protection Circuit Breaker 3P 1-1.6A 72735

€31.74 Tax included
€31.74

Eaton Motor Protection Circuit Breaker 3P 1-1.6A 72735

€31.74
Tax included

-20€

EXTRA

Add the coupon code in the payment page

Limited-time promotion
qty

Eaton Motor Protection Circuit Breaker 3P 1-1.6A 72735

€31.74

Buy it within and receive it from Thursday, 25 September
Two-year warranty
Secure Payment
Easy return within 14 days

The motor protection switch is installed on the cable that feeds the motor and, when the motor stops due to a mechanical effect or (in three-phase systems) because a phase is missing, it detects an excessive absorption and automatically cuts off the electrical energy, safeguarding the integrity of the motor.


Features:

  • Eaton series
  • 3 poles - size PKZM0
  • With adjustable thermal release and instantaneous magnetic release
  • Phase failure sensitive
  • Screw or snap-on fixing
  • With screw terminals
  • Dome mounting dimensions 45 mm
  • Rated operational voltage Ue 690V
  • Degree of protection IP20
  • Rated operational current 1.6 A
  • Power 0.55 kW
  • Overload releases 1 - 1.6 A
  • Rated frequency 40 - 60 Hz
  • Ambient operating temperature min -25 °C
  • Ambient operating temperature max +55 °C
  • Protection rating of connection terminals IP00
  • Ambient temperature storage -40 - 80 °C
  • Ambient temperature daytime -25 - +55 °C
  • Ambient temperature in storage -25 - 40 °C
  • Altitude max 2000 mm
  • Main conductor connection sections single-wire or stranded screw terminals 18 - 10 AWG
  • Main conductor connection sections screw terminals stripping length 10 mm
  • Specified tightening torque for terminal screws Main cable 1.7 Nm
  • Specified tightening torque for terminal screws Control circuit cables 1 Nm
  • Rated impulse withstand voltage [Uimp] 6000 VAC
  • Overvoltage category/ pollution degree III/3
  • Height 93 mm
  • Width 45 mm Depth 76 mm
  • Depth 76 mm

Data sheet

Type:
Motor protection
Modules:
3
Poles:
3P
Power:
150KA
Amps:
1-1.6 To