Cable FG17 1X2,5mmq 450/750V Black 100 Metres
Cable FG17 1X2,5mmq 450/750V Black skein 100 M for low voltage, reaction to fire compliant with CPR Regulation 305/2011/EU.
- Baldassari cavi
- Icel
- La Triveneta
- Prysmian
Cable FG17 1X2,5mmq 450/750V Black 100 Metres
Cable FG17 1X2,5mmq 450/750V Black 100 Metres
Tax included
-20€
EXTRA
Add the coupon code in the payment page
Cable FG17 1X2,5mmq 450/750V Black 100 Metres
Pay in installments with KlarnaFeatures:
- Conductor: bare copper, flexible training, class 5
- Insulation: elastomeric crosslinked LS0H, quality G17
- Nominal voltage Uo/U: 450/750 V
- Maximum operating temperature: 90°C
- Minimum operating temperature: -30°C (without mechanical stress)
- Maximum temperature of short circuit: 250°C
- Good sliding properties in pipes, good abrasion resistance, excellent spellabilità
- Minimum temperature of installation: -15°C
- The minimum bending radius recommended: 4 times the cable diameter
- The maximum tensile stress recommended: 50 N/mm2 of the section of the copper
- Diameter approximate conductor 2.0 mm
- Average thickness of insulation-0.8 mm
- Max outside diameter 4.1 mm
- Electrical resistance max at 20°C /km 7,98.
Suitable in environments where it is essential to the preservation of the people: schools, offices, theatres, subways, hospitals, places of worship, malls and places of public entertainment and entertainment. For installation within a pipe, or recessed or closed systems similar. For fixed installation and protected within lighting fixtures or equipment, break and command. When the installation is protected inside of equipment or interruption of command for this cable is permitted for voltages up to 1000 V ac or 750 V in c.c. in relation to the earth. Suitable for installations beam in environments with a greater risk in the event of a fire. Not suitable for laying outdoors.
Reference Regulation the Construction Products 305/2011 EU Norm EN 50575: Given the properties of the limit the development of the fire and noxious fumes, the cable is suitable for power supply in buildings and other civil engineering works.
Reaction to fire:
- Standard EN 50575:2014+A1:2016
- Class Cca-s1b, d1, a1
- Classification: (CEI UNEL 35016) EN 13501-6
- The emission of heat and fumes during the development of the flame
- The propagation of the flame vertical EN 60332-1-2
- Corrosive gases and alogenidrici: EN 60754-2
- Density of smoke (transmittance): EN 61034-2
- Notified body: 0051 - IMQ
- C AND 2019.
Data sheet
- Colour: Black
- Section: 2.5 mmq
- With yellow/green: No
- Number of cables: 1
: 127

