Telemecanique TeSys D 40A 3P 220VAC Contactor LC1D40AM7
Schneider TeSys LC1D contactor with the following characteristics:
- Number of poles: 3
- Rated operating voltage: Ue: <= 690 V "AC" 25...400 Hz Power circuit - <= 300 V DC Power circuit
- Conventional thermal current in open air: 10A at <60 °C for signaling circuit - 50A at <60 °C for Power circuit
- Control circuit type: AC at 50/60 Hz
- Auxiliary contact composition: 1 NO + 1 NC
- Minimum switching voltage: 17V for signaling circuit
- Minimum switching current: 5 mA per signaling circuit

Telemecanique TeSys D 40A 3P 220VAC Contactor LC1D40AM7
Tax included
-20€
EXTRA
Add the coupon code in the payment page
Frequently bought together
LC1D40AM7 is a 3-pole TeSys D contactor from Schneider Electric for motor applications up to 18.5 kW at 400V.
It includes a 220V 50/60 Hz AC coil and integrated 1NO+1NC auxiliary contacts and can be used in safety applications due to its certified NC mirror contact. Compact, DIN-rail-mounted, it ensures high reliability and durability. Available worldwide, it is certified to various standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium (RoHS/REACH) compliant.
Benefits:
- Compact product, 55 mm wide, for DIN rail and panel mounting
- Separation between power and control circuits, easy front access to coil and auxiliary contact connections
- Equipped with a 220 V AC coil that can be powered at 50 Hz or 60 Hz
- Features 2 built-in 1NA+1NC auxiliary contacts
- High electrical durability, guaranteed for 1.6 million cycles at 40 A AC-3 440 V
- Environmentally friendly product performance
Rated operating voltage:
- <= 690 V "AC" 25...400 Hz Power circuit
- <= 300 V DC Power circuit
Rated use current:
- 60 A 60 °C) AC AC-1 for Power circuit at <= 440 V
- 40 A 60 °C) AC AC-3 for Power circuit at <= 440 V
- 40 A 60 °C) AC AC AC-3e for Power circuit at <= 440 V
Motor power KW:
- 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
- 11 kW at 220...230 V AC 50/60 Hz (AC-3)
- 22 kW at 415...440 V AC 50/60 Hz (AC-3)
- 22 kW at 500 V AC 50/60 Hz (AC-3)
- 30 kW at 660...690 V AC 50/60 Hz (AC-3)
- 9 kW at 400 V AC 50/60 Hz (AC-4)
- 18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
- 11 kW at 220...230 V AC 50/60 Hz (AC-3e)
- 22 kW at 415...440 V AC 50/60 Hz (AC-3e)
- 22 kW at 500 V AC 50/60 Hz (AC-3e)
- 30 kW at 660...690 V AC 50/60 Hz (AC-3e)
Motor power in hp:
- 5 hp at 230/240 V for 1 phase motorsCA 50/60 Hz
- 10 hp at 230/240 V for 3 phase motorsCA 50/60 Hz
- 30 hp at 575/600 V for 3 phase motorsCA 50/60 Hz
- 10 hp at 200/208 V for 3 phase motorsCA 50/60 Hz
- 3 hp at 115 V for 1 phase motorsCA 50/60 Hz
- 30 hp at 460/480 V for 3-phase motorsCA 50/60 Hz
Conventional thermal current in open air:
- 10A at <60 °C per Circuit signaling
- 50A at <60 °C for power circuit
Rated closing power Irms:
- 140 A AC for signaling circuit complying with IEC 60947-5-1
- 250 A DC for signaling circuit complying with IEC 60947-5-1
- 800 A at 440 V for power circuit complying with IEC 60947
Rated short-time allowable current ICW:
- 320 A at <40 °C - 10 s for Power Circuit
- 720 A at <40 °C - 1 s per Power Circuit
- 72 A at <40 °C - 10 min per Power Circuit
- 165 A at <40 °C - 1 min per Power circuit
- 100 A - 1 s per signaling circuit
- 120 A - 500 ms per signaling circuit
- 140 A - 100 ms per signaling circuit
Associated fuse gauge:
- 10 A gG for signaling circuit complying with IEC 60947-5-1
- 80 A gG at <= 690 V Type 1 coordination for Power circuit
- 80 A gG at <= 690 V coordination Type 2 for Power circuit
Rated insulation voltage:
- 600 V CSA certified Power circuit
- 600 V UL certified Power circuit
- 690 V complying with IEC 60947-1 signaling circuit
- 600 V CSA certified signaling circuit
- 600 V UL certified signaling circuit
- 690 V complying with IEC 60947-4-1 Power circuit
Connections - terminals:
- Control circuit screw clamps: 2 1...2.5 mm² - cable stiffness: flexible with cable end
- Control circuit screw clamps: 1 1...4 mm² - cable stiffness: flexible without cable end
- Control circuit screw clamps: 2 1...4 mm² - cable stiffness: flexible without cable end
- Control circuit screw clamps: 1 1...4 mm² - cable stiffness: flexible with cable end
- Control circuit screw clamps: 1 1...4 mm² - cable stiffness: solid without cable end
- Control circuit screw clamps: 2 1...4 mm² - cable stiffness: solid without cable end
- EverLink connectors for BTR screws Power circuit: 1 1...35 mm² - cable stiffness: flexible without cable end
- EverLink connectors for BTR screws Power circuit: 2 1...25 mm² - cable stiffness: flexible without cable end
- EverLink connectors for BTR screws Power circuit: 1 1...35 mm² - cable stiffness: flexible with cable end
- EverLink connectors for BTR screws Power circuit: 2 1...25 mm² - cable stiffness: flexible with cable end
- EverLink connectors for BTR screws Power circuit: 1 1...35 mm² - cable stiffness: solid without cable end
- EverLink connectors for BTR screws Power circuit: 2 1...25 mm² - cable stiffness: solid without hollow end
Tightening torque:
- Control circuit: 1.7 Nm - on screw clamps - with Ø 6 mm flat screwdriver
- Control circuit: 1.7 Nm - on screw clamps - with Philips screwdriver No 2
- Power circuit: 8 Nm - on EverLink connectors for BTR screws - cable 25...35 mm² hex 4 mm
- Power circuit: 5 Nm - on EverLink connectors for BTR screws - cable 1...25 mm² hex 4 mm
- Control circuit: 1.7 Nm - on screw clamp terminals - with pozidriv screwdriver No 2
- Power circuit: 2.5 Nm - on screw clamp terminals - with pozidriv screwdriver No 2
Mechanical robustness:
- Open contactor vibration (2 Gn, 5...300 Hz)
- Contactor vibration closed (4 Gn, 5...300 Hz)
- Closed contactor shocks (15 Gn for 11 ms)
- Open contactor shocks (10 Gn for 11 ms)
Characteristics:
- Mechanical life span: 6 Mccycles
- Control circuit type: AC at "50/60 Hz"
- Auxiliary contact composition: 1 NO + 1 NC
- Auxiliary contact type: Mechanically linked type 1 NO + 1 NC complying with IEC 60947-5-1, mirror contact type 1 NC complying with IEC 60947-4-1
- Signaling circuit frequency: 25 to 400 Hz
- Minimum switching voltage: 17V per signaling circuit
- Minimum switching current: 5 mA per signaling circuit
- Insulation resistance: > 10 MOhm per signaling circuit
- IP degree of protection: IP20 Front side complies with IEC 60529
- M2 contact compatibility
- Protection coverage Con
- Rated breaking capacity: 800 A at 440 V per Power circuit complying with IEC 60947
- Average impedance: 1.5 mOhm 50 Hz - Ith 60 A per Power Circuit
- Power dissipation per pole: 2.4 W AC-3 - 5.4 W AC-1 - 2.4 W AC-3e
- Pollution degree: 3
- Rated impulse withstand voltage [Uimp]: 6 kV in accordance with IEC 60947
- Coil technology: without integrated suppressor module
- Safety reliability level: B10d = 1369863 cycles Contactor with rated load complies with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load complies with EN/ISO 13849-1
- Maximum cycle life: 3600 cycles/h at <60 °C
- VA inrush power: 140 VA 60 Hz 0.75 20 °C) - 160 VA 50 Hz 0.75 20 °C)
- VA holding power consumption: 13 VA 60 Hz 0.3 20 °C) - 15 VA 50 Hz 0.3 20 °C)
- Heat dissipation: 4...5 W at 50/60 Hz
- Operation time: 4...19 ms opening - 12...26 ms closing
- No-overlap time: 1.5 ms on deactivation between NC and NO contact, 1.5 ms on activation between NC and NO contact
- Installation: Rail - Plate
- Allowable temperature near the device: -40/+60 °C, -60/+70 °C with derating
- Operating altitude: 0 to 3000 m
- Fire resistance: 850 °C complying with IEC 60695-2-1
- Fire resistance: V1 in accordance with UL 94
- IP degree of protection: IP20 Front side complies with IEC 60529
- Protective treatment: TH complying with IEC 60068-2-30
- Climatic sealing: Conforms to IACS E10 moist heat exposure, conforms to IEC 60947-1 Annex Q category D moist heat exposure
- Dimensions: height 122 mm - width 55 mm - depth 120 mm
- Weight 850 grams
Data sheet
- Type:
- Contactors