Schneider TeSys LC1D Contactor 3P 32A AC3 220V AC LC1D32M7


SNR LC1D32M7 3389110351088

Schneider TeSys LC1D contactor with the following characteristics:

  • Number of poles: 3
  • Rated operating voltage
  • Ue: <= 690 V "AC" 25...400 Hz Power circuit - <= 300 V DC Power circuit
  • Conventional thermal current in open air: 10A at <60 °C for signaling circuit - 50A at <60 °C for Power circuit
  • Control circuit type: AC at "50/60 Hz"
  • Auxiliary contact composition: 1 NO + 1 NC
  • Minimum switching voltage: 17V for signaling circuit
  • Minimum switching current: 5 mA per signaling circuit
Request info about this product

Schneider TeSys LC1D Contactor 3P 32A AC3 220V AC LC1D32M7

€109.29 Tax included
€109.29

Schneider TeSys LC1D Contactor 3P 32A AC3 220V AC LC1D32M7

€109.29
Tax included

-20€

EXTRA

Add the coupon code in the payment page

Limited-time promotion
qty

Schneider TeSys LC1D Contactor 3P 32A AC3 220V AC LC1D32M7

€109.29

Buy it within and receive it from Tuesday, 23 September
Two-year warranty
Secure Payment
Easy return within 14 days

LC1D32M7 is a 3-pole TeSys D contactor from Schneider Electric for motor applications up to 15 kW at 400 V. It includes a 220V 50/60 Hz AC coil and integrated 1NO+1NC auxiliary contacts and can be used in safety applications due to its certified NC mirror contact. Compact, DIN-rail-mounted, it ensures high reliability and durability. Available worldwide, it is certified to various standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium (RoHS/REACH) compliant.


Advantages:

  • Compact product, 45 mm wide, for DIN rail and panel mounting
  • Separation between power and control circuits, easy front access to coil and auxiliary contact connections
  • Equipped with a 220 V AC coil that can be powered at 50 Hz or 60 Hz
  • Features 2 built-in 1NA+1NC auxiliary contacts
  • High electrical durability, guaranteed for 1.6 million cycles at 32 A AC-3 440V


Rated operating voltage:

  • <= 690V "AC" 25...400 Hz Power circuit
  • <= 300 V DC Power circuit

Rated use current:

  • 32 A 60 °C) "AC" AC-3 for Power circuit at <= 440 V
  • 50 A 60 °C) "AC" AC-1 for Power circuit at <= 440 V
  • 32 A 60 °C) "AC" AC-3e for Power circuit at <= 440 V

Motor power:

  • 7.5 kW at 220...230 V "AC" "50/60 Hz" (AC-3)
  • 15 kW at 380...400 V "AC" "50/60 Hz" (AC-3)
  • 15 kW at 415...440 V "AC" "50/60 Hz" (AC-3)
  • 18.5 kW at 500 V "AC" "50/60 Hz" (AC-3)
  • 18.5 kW at 660...690 V "AC" "50/60 Hz" (AC-3)
  • 7.5 kW at 400 V "AC" "50/60 Hz" (AC-4)
  • 7.5 kW at 220...230 V " AC" "50/60 Hz" (AC-3e)
  • 15 kW at 380...400 V "AC" "50/60 Hz" (AC-3e)
  • 15 kW at 415...440 V "AC" "50 /60 Hz" (AC-3e)
  • 18.5 kW at 500 V "AC" "50/60 Hz" (AC-3e)
  • 18.5 kW at 660...690 V "AC" "50/60 Hz" (AC-3e)

Motor power in hp:

  • 2 hp at 115 V for 1 phase motors "AC" "50/60 Hz"
  • 5 hp at 230/240 V for 1 phase motors "AC" "50/60 Hz"
  • 7.5 hp at 200/208 V for 3 phase motors "AC" "50/60 Hz"
  • 10 hp at 230/240 V for 3 phase motors "AC" "50/60 Hz"
  • 20 hp at 460/480 V for 3 phase motors "AC" "50/60 Hz"
  • 30 hp at 575/600 V for 3 phase motors "AC" "50/60 Hz"

Conventional thermal current in open air:

  • 10A at <60 °C per circuit signaling
  • 50A at <60 °C for power circuit

Rated closing power Irms:

  • 140 A "AC" for signaling circuit complying with IEC 60947-5-1
  • 250 A DC for signaling circuit complying with IEC 60947-5-1
  • 550 A at 440 V for power circuit complying with IEC 60947

Rated short-time allowable current:

  • 260 A at <40 °C - 10 s for Power Circuit
  • 430 A at <40 °C - 1 s for Power Circuit
  • 60 A at <40 °C - 10 min per Power Circuit
  • 138 A at <40 °C - 1 min per Power circuit
  • 100 A - 1 s per signaling circuit
  • 120 A - 500 ms per signaling circuit
  • 140 A - 100 ms per signaling circuit

Associated fuse gauge:

  • 10 A gG per signaling circuit complying with IEC 60947-5-1
  • 63 A gG at <= 690 V coordination Type 1 for Power circuit
  • 63 A gG at <= 690 V coordination Type 2 for Power circuit

Rated insulation voltage:

  • 690 V complying with IEC 60947-4-1 Power Circuit
  • 600 V CSA certified Power circuit
  • 600 V UL certified Power circuit
  • 690 V complying with IEC 60947-1 signaling circuit
  • 600 V CSA certified signaling circuit
  • 600 V UL certified signaling circuit

Features:

  • Mechanical life span: 15 Mcicycles
  • Control circuit type: AC at "50/60 Hz"
  • Auxiliary contact composition: 1 NO + 1 NC
  • Mechanically linked type 1 NO + 1 NC complying with IEC 60947-5-1
  • Mirror contact type 1 NC complying with IEC 60947-4-1
  • Minimum switching voltage: 17V per signaling circuit
  • Minimum switching current: 5 mA per signaling circuit
  • Insulation resistance: > 10 MOhm per signaling circuit
  • IP rating: IP20 Front side complies with IEC 60529
  • Dimensions and weight: height 85 mm - width 45 mm - depth 92 mm weight 375 grams

Data sheet

Type: